Terminals to fit Anderson PP15/30/45 Powerpole housings.
Please select the terminal to match your cable size from the drop-down list (one terminal required per housing)
Sold individually.
Further information
Terminal crimping - The 15A and 30A terminals can be crimped to the cable conductor using a suitable tool (we recommend P00804) or soldered. We do not stock a dedicated tool for the 45A terminals so we recommend folding the crimp 'wings' over the conductor and soldering.
Terminal insertion - Insert the terminal into the connector housing so that the step at the end of the terminal slides along the surface of the sprung metal tab within the housing. Continue pushing the terminal into the housing until a sharp click is heard, which indicates that the tab has latched into place behind the step and the terminal is locked in place.
Terminal removal - Press the sprung metal tab in the housing fully flat using a suitable tool (so that it clears the step on the terminal body) and withdraw the terminal.