The Lynx Class-T Power In (M10) module is part of the Victron Energy Lynx DC distribution system and is used to protect against extremely large short-circuit currents that can be produced by lithium batteries under fault conditions (due to their very low internal resistance). This module can house two 225A-400A Class-T fuses which have a very high interrupt capacity of 20kA DC and very fast blow characteristics, so offer the best chance of protecting your system from serious damage.
Inside the Lynx Class-T Power In (M10) there are positive and negative busbars, with two Class-T fuse locations from the positive busbar leading to two separate M10 studs for the positive battery cable connections, and a further two M10 studs for the negative connections. The studs accept copper tube terminals up to 120mm² in size and there is also a ground connection from the negative busbar, if one is required. The Lynx Class-T Power In (M10) should ideally be used in conjunction with a Lynx Distributor (M10) for protection of DC loads, and can be combined with any of the other modules in the Lynx range that use M10 inter-connection studs.
Each parallel connected battery, or each string of series-connected batteries should be fused, so this module can protect either two batteries in a 12V system that are connected in parallel, or two strings of series-connected batteries for higher voltages. For more than two parallel connected batteries or more than two series-connected strings, further Lynx Class-T Power In (M10) modules will need to be connected to the first to provide sufficient fuse locations.
Important: This module accepts only 225A, 250A, 300A, 350A, or 400A Class-T fuses (see further information below). Smaller and larger rated fuses in the Class-T range have different dimensions and will not fit the fuse locations in the Lynx Class-T Power In (M10).
This unit has a nominal current rating of 1000A for 12V, 24V or 48V systems, and M10 module connection bars and studs.
Further information
The following Class-T fuses can be used with this module:
225A | 250A | 300A | 350A | 400A
- Voltage rating: 9-60V DC
- Current rating: 1000A DC continuous
- Busbar connections: M10
- Fuse connections: 3/8"
- Module interconnection studs: M10
- Max. copper tube terminal size: 120mm2
- Terminal bolt torque: 33Nm
- Enclosure material: ABS
- Busbar material: Tinned copper
- Busbar cross-section: 8mm x 30mm (240mm²)
- Overall dims: 279 (L) x 169 (W) x 97 (H) mm
- Operating temperature: -40 to +60°C
- Ingress protection rating: IP22
Part Number : LYN060404010
Bar Code : 8719076062967